K10 DATA VISUALIZATION

Charts like instruments.

Every chart states its unit, its conditions and its source. Illustrative data says so. Charts animate once on entry and always carry a text alternative.

V.01 · KPI TILES & SPARKLINES
OEE▲ 1.2
86%
Line 2 · last 14 shifts · illustrative
AVAILABILITY▲ 0.4
93%
Line 2 · last 14 shifts · illustrative
MTBF▲ 6
142h
Line 2 · last 14 shifts · illustrative
ENERGY / PART▼ 0.02
0.41kWh
Line 2 · last 14 shifts · illustrative
V.02 · OEE WATERFALL

Availability × Performance × Quality

100
−7
−5
−2
86 %
Planned timeAvailability lossPerformance lossQuality lossOEE
Line 2, Holmgaard Aarhus, Aug 2025, per ISO 22400-2 · illustrative
TEXT ALTERNATIVEPlanned 100 %. Availability 93 % (−7). Performance 94.6 % (−5). Quality 97.7 % (−2). OEE 86 %.
V.03 · TORQUE–SPEED CHARACTERISTIC

PX 080 · i = 10

T₂ [Nm] n₁ [rpm] 416 0 6,000
T₂N rated, typ. T₂max, max.
Test bench data, 25 °C ambient, S1 duty · illustrative
V.04 · MACHINE-STATE TIMELINE

Line 2 · 3 shifts · 2025-08-14

VX5-01
VX5-02
Lathe 4
Assy 2
06:0014:0022:0006:00
RUNNING WARNING · hatched FAULT · lined PLANNED STOP
Source: Hartwerk Connect, 1-min resolution · illustrative. Patterns make states distinguishable without color.
V.05 · SPC CONTROL CHART

Bore ⌀20 H7 · X̄ chart

UCL 20.019
X̄ 20.010
LCL 20.001
n = 5 per subgroup, CMM at 20 °C · point 14 out of control (◆) · illustrative
V.06 · PARETO OF DOWNTIME CAUSES

Top causes · min / month

184
121
88
42
30
18
Tool change Material wait Jam Cleaning Sensor Other
Orange line = cumulative %, 80 % reached at cause 3 · illustrative
V.07 · CAPACITY HEATMAP

Utilization · shift × machine

EARLYLATENIGHT VX5-01 92 % 88 % 61 % VX5-02 95 % 90 % 72 % VX5-03 80 % 76 % — Lathe 4 70 % 64 % 40 % Grind 1 55 % 48 % — Assy 2 98 % 94 % 81 %
0 %100 %
Week 34 · planned utilization · illustrative
V.08 · ENERGY LOAD PROFILE

Hall 3 · kW over 24 h

00:0006:0012:0018:0024:00
Peak 412 kW at 07:00 (copper) · 15-min mean · illustrative
V.09 · SANKEY · ENERGY FLOW

Hall 3 · MWh / month

GRID 1,000 SPINDLES 450 HVAC 250 COMPRESSED AIR 160 HEAT RECOVERY 100
Metered, Aug 2025 · lighting 50 not labeled · illustrative
V.10 · PROJECT GANTT

Retrofit Line 2 · weeks

Engineering
Parts supply
Customer FAT
Installation
Ramp-up
Sign-off
W36W40W44W48
Blue = milestone owned by customer (action required) · illustrative
V.11 · DATA TABLE · SORT, FILTER, BULK, EXPORT
2 SELECTED Export CSVAdd selected to quote
PX 200 2,100 3,000 41.5
PX 160 1,200 3,500 24.0
PX 120 620 4,500 11.8
PX 080 260 6,000 4.4
PX 060 110 7,000 2.1
PX 040 40 8,000 0.9

Chart rules

Units in brackets

Axis labels as quantity [unit]: T₂ [Nm], n₁ [rpm].

Typ. vs. max.

Typical = solid line. Maximum / limit = dashed. Always in legend.

Conditions line

Temperature, duty, test setup under every chart.

Timestamps

ISO 8601, 24 h clock, timezone on live data.

Illustrative label

Any non-measured data says "illustrative" in the source line.

Text alternative

Summary + data table behind a disclosure on every chart.